modtran
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
modtran [2025/02/19 09:54] – admin | modtran [2025/02/19 13:33] (current) – admin | ||
---|---|---|---|
Line 1: | Line 1: | ||
- | ==== Radiative Forcing Experiments with Modtran ==== | + | ===== Radiative Forcing Experiments with Modtran |
- | work in progress | + | |
+ | Reproduce with: {{ : | ||
+ | |||
+ | Also at [[https:// | ||
+ | |||
+ | ==== Using Modtran online at U. Chicago ==== | ||
- | === online Modtran at U. Chicago === | ||
{{: | {{: | ||
- | We use the website | + | We use the website [[https:// |
- | [[https:// | + | |
- | for the calculations. | + | |
We assume a certain profile of atmospheric temperature is in | We assume a certain profile of atmospheric temperature is in | ||
Line 15: | Line 17: | ||
For all experiments here, the temperature profile is //1976 U.S. Standard Atmosphere//, | For all experiments here, the temperature profile is //1976 U.S. Standard Atmosphere//, | ||
- | the initial assumed equilibrium profile, in blue, with 300 ppm of CO< | + | the initial assumed equilibrium profile, in blue, with 300 ppm of CO< |
+ | ==== Upward spectral irradiance at 20 km ==== | ||
+ | For reasons explained below, experiments to explore adjusted radiative equilibrium are best | ||
+ | done by monitoring the upward irradiance to 20 km, rather than the top of the atmosphere. | ||
- | === Spectral Irradiance === | + | ^ Going from 300 ppm to 0 ppm CO< |
- | All are U.S. Standard Atmosphere and no clouds | + | |{{ : |
- | {{ : | + | |
- | {{ : | + | |
- | {{ : | + | |
- | {{ : | + | |
- | {{ : | + | |
+ | ^ Going from 300 ppm to 600 ppm CO< | ||
+ | |{{ : | ||
- | === The GUI === | + | ^ Alternatively, |
+ | | {{ : | ||
+ | |||
+ | ==== Adjusted equilibrium temperatures ==== | ||
+ | |||
+ | Doubling CO< | ||
+ | |||
+ | ^ With specific humidity constant ^ | ||
+ | | {{ : | ||
+ | |||
+ | ^ With specific humidity increasing to maintain initial relative humidity. ^ | ||
+ | | {{ : | ||
+ | |||
+ | ==== Experiments at 70 km ==== | ||
+ | |||
+ | ^At 70 km, there is a spike in the CO< | ||
+ | |{{ : | ||
+ | |||
+ | ^ Double CO< | ||
+ | {{ : | ||
+ | |||
+ | ^Smaller temperature increase is needed to restore equilibrium. Increasing stratospheric temperature is not a good approximation for what happens in restored equilibrium. | ||
+ | | {{ :: | ||
+ | |||
+ | ==== The GUIs ==== | ||
Line 39: | Line 65: | ||
^ 0ppm20km ^ 300ppm20kmch136 ^ | ^ 0ppm20km ^ 300ppm20kmch136 ^ | ||
|{{ :: | |{{ :: | ||
+ | |||
+ | ^ 600ppm70kmt105rh ^ | ||
+ | |{{ : | ||
modtran.1739980465.txt.gz · Last modified: 2025/02/19 09:54 by admin